- Support Links
- Email Tech Support
- Calculations
- Downloads
- Documentation
- FAQs
- RMA Guidelines
- RMA Fax Form
- RMA Online
- Software
Knowledge Base
- Site Map
|
KBridge 5.10-00 - KBridge kernel for Atheros radios (TeraMax [previously Marquee], KB20,
etc.)
KBridge 4.46-01 - KBridge kernel for Hermes I, Hermes II and Prism
radios (AP-Plus, KB10, etc.)
KBridge Kernel for Atheros radios
v5.10-00 – May 6, 2005
Features:
- All Bin files for radio types are now v 5.10.
- Added AES and WEP encryption for TurboCell links deployed with Atheros based radios.
- Added Atheros Interoperability with Hermes I/II and Intersil radios. Selecting Hybrid mode in Terabeam Configurator v5.10 allows Atheros based radios the ability to communicate with legacy TurboCell (TC).
- Added multi rate client support for Atheros equipped TC base stations. Hybrid base stations in TC 802.11G mode will transmit to TC 802.11b and TC 802.11g clients at the individual clients set transmit rates. This method optimizes overall throughput by reducing re-transmit rates when CPE-Base link quality standards are adhered.
- Calibration data is now permanently written to non-volatile memory on KN-150/250/105/205 units using Atheros radios (e.g. in Marquee).This method prevents calibration data loss if forced reload is utilized.
- Improved support for Ethernet in Auto duplex mode.
- Utilizes Terabeam Configurator v5.10-00-041813.
Known Issues:
- In Hybrid mode the base with *6200E-A shows as P-P controller in TC station entries of satellite.
- Channels 1&11 not available in TurboCell 802.11g selection.
- If you utilize Auto Channel Scanning the unit should be in Hybrid mode and configured as an ISP Base Station. The Channel and Network ID must be the same value in TurboCell B/G modes.
- Hermes II ETSI cards report channels 12 and 13 with some v5.10 binary files.
- FlashROM builds with software encryption option, the binary image size cannot be reduced to satisfy upload requirements.
- V 5.10 BETA testers utilizing compact Flash/ FlashROM units must load new binary from forced reload.
v5.02-03 January 26, 2005
Features
- 4.9GHz (Public Band) TurboCell with 36Mbps maximum transmit rate
- Polling Base Station Mode or Point-Point (license key enabled)
- Utilizes Terabeam Configurator (v5.02-02-011718)
v5.02-02 December 06, 2004
Features
v5.02-01 September 10, 2004
Features
- Added an SNMP secuity feature that protects the transfer of data over your network.
- Wireless equipment manufacturers must now calibrate Atheros radio power settings during the manufacturing/production
process.
- Radio firmware for Hermes II radios was updated from v1.26 to v2.26.
Issues Fixed
- Corrected a packet framing issue to improve future system interoperability.
Known Issues
Version 5.02 of the TurboCell Kernel incorporates a fundamental protocol change related to packet framing, and
is incompatible with Version 5.00 of the TurboCell Kernel. We recommend that you upgrade any KB20 hardware devices
(Wireless Base Stations, Wireless Repeater Units, Wireless Clients) to Version 5.02 because future releases of
the TurboCell Configurator will be based on this version. However, if you upgrade to Version 5.02 from Version
5.00, you must upgrade every Version 5.00 hardware device in your network. It is also imperative that you upgrade
any Version 5.00 satellite/client stations in your network before you upgrade the Version 5.00 base stations in
your network.
You also need to make sure that you are using the latest version (v5.02) of the TurboCell Windows Configurator
with v5.02 of the TurboCell Kernel.
 KBridge
kernel for Hermes I, Hermes II
and Prism radios
v4.46-01 December 20, 2004
Issues Fixed
v4.46-00 December 05, 2004
Issues Fixed
- Updated Hermes II driver (supporting mPCI and PCMCIA radios)
- Configuration security (KBsec)
- Ethernet stability and burst management improvements
- Improved DHCP server compatibility when NAT enabled
- Reduced system latency in dual radio configurations where first interface is configured as TurboCell satellite
- Retransmit counter boundary check added to address "IP Freeze" issue
Note :Some networks may still experience this issue. Transmit bit rate should be adjusted at CPE Station(s)
and Base, to ensure that frame retransmit rate is less than 10% to minimize occurrences
-
TCP stack fixes (WARP/PAR)
- Repaired Software Key issue that caused units loaded with Hermes I encryption-enabled builds to lock
- Repaired issue that caused default IP address (198.17.74.245) to be sent to Radius server
Known Issues
v4.45-01/v5.00-01 June 14, 2004
Issues Fixed
- Fixed an issue in v4.45-00 where ORiNOCO 5v radios could not start in Evotech/Teletronics Compact Flash builds.
Known Issues
- In v4.45-00, some ORiNOCO 3.3 and 5v radios could not start up in Teletronics board. The decision was made to
support ORiNOCO 5v radios, but not ORiNOCO 3.3v radios.
v4.45-00 May 17, 2004
New Features
- Support for Agere Hermes II PCMCIA radios.
- AP support for Intersil Prism 2.5 radios, including selectable WEP Authentication modes.
- Enhanced MAC Authentication Access Control List features.
- Enhanced RADIUS authentication, including support for RADIUS realms.
- Configurable maximum users per interface.
Issues Fixed
- Fixed manual full duplex mode on KN-1xx/KN-2xx series boards.
- Hermes I FCC-related improvements for TurboCell. Base units were sending SNMP Link up/down traps every two seconds
when no remote satellites were connected. Those traps are no longer sent.
- Fixed occasional Hermes radio lockup at startup.
- Made Ethernet burst adjustments to adjust the auto-negotiation process in KN-100/KN-200 and KN-105/KN-205 boards.
- Fixed a bug where the DHCP Client could not handle changes in some DHCP Options.
- Fixed a bug where the KBridge Bandwidth Throttle variance exceeded the 10% threshold for data rates above 256
kbps.
Known Issues
- Upgrading from releases prior to v4.44-00 required the same-sized .bin file. However, this requirement changed
with release v4.44-00, and releases following v4.44-00 use larger .bin files rather than the same- sized .bin fies.
Therefore, you may not be able to directly upgrade to v4.45-00 of the TurboCell Kernel from v4.43k or earlier.
If you are experiencing problems upgrading to version 4.45-00 from a release earlier than v4.44-00, first upgrade
to v4.44-00. Once v4.44-00 is installed, you can then upgrade to v4.45-00.
- Upgrade to v4.44-00
- Upgrade
to v4.45-00
- You must use the v5.00-00 Windows Configurator with the v4.45-00 TurboCell Kernel. You should replace previously
saved versions of your configuration with new configuration backups from the v5.00 Configurator.
- Kernel files are now radio-specific. For example, one firmware image may have the necessary drivers for Hermes
1 and Prism 2.0/2.5-based radios, but a different firmware file is required for Hermes II radios.
- We recommend that you match the Ethernet Setup parameters for all connecting network devices. For example, if
you configure your Ethernet port on the Ethernet Setup screen to 100 Mbit/sec Full Duplex, then we recommend that
you also set the connecting device to 100 Mbit/sec Full Duplex.
v4.44-02 February 13, 2004
Issues Fixed
- Base units were sending SNMP Link up/down traps every two seconds when no remote satellites were connected.
Those traps are no longer sent.
- Some Xbox live conections could not be established through NAT. Now Xbox live connections are functioning normally.
v4.44-01 December 19, 2003
Features
- Added support for RadioLAN radios.
- Added full support for both passive FTP and active FTP through NAT.
- Changed the packet aging limit to 1 second from 3 seconds.
- Added the bin file name to the Description field of the System Information Monitor screen.
- Included new bin/key for new SG-4001 product (TurboCell only client software).
Issues Fixed
- Previous releases incorrectly always displayed the IP address as 198.17.74.254 (the default address) when the
WARP and DHCP features were enabled. The fix now displays the correct IP address of the device.
- Fixed a TCP Checksum error that affected FTP, PPTP, and RTSP through NAT.
v4.44-00 October 22, 2003
Features
- Wireless HotSpot Access Point support (WARP)
- IP Tunneling for TurboCell Builds
- Automatic Channel Scan for TurboCell
- 802.1x support for TurboCell builds (802.11 AP mode only), and support for EAP-TLS, EAP-TTLS, EAP-MD5, and PEAP
authentication
- Hardware Watchdog Timer on KN-100/KN-200 system boards
Issues Fixed
- Improved Intersil radio speed settings
- Added more efficient authentication through RADIUS
- Added full support for passive FTP (active FTP not supported for TurboCell clients) through NAT
- SNMP Traps now broadcast over all interfaces
- Enhanced TurboCell protocol to improve latency issues
Known Issues
- TurboCell Base Station (AP1000, KN100/200, FlashROM Builds) support for 128 clients (satellites) has not been
released for general availability. However, KarlNet may release this extended license for use in certain applications.
Customers may apply for a 128 client extended license through Terabeam Wireless Customer Services at techsupport@terabeam.com.
- If you change from an ORiNOCO Gold card to an ORiNOCO Silver card, you can still select the 128-bit WEP option
and enter a 128-bit key in the Configurator. However, ORiNOCO silver cards do not support 128-bit WEP. The KarlBridge
kernel uses only the 64-bit portion of that key. To work around this issue, when you want to replace the gold card
with a silver one, select Open bin file/Upload rather than Open remote/Upload. Note that this problem only exists
when changing from a Gold card to a Silver card. Changing from a Silver card to a Gold card always works fine.
- For FlashROM units, if you have problems saving a config (.cnf) file or uploading a new kernel on top of v4.44,
check your BIOS settings. This is due to a memory conflict. Make sure you disable the devices that you are not
using. Specifically, in your peripherals settings, set your "IDE Primary Master PIO" to Mode 0 instead
of Auto.
v4.43k June 05, 2003
Features
- Support for KN-100/KN-200 system boards
- Updated Agere ORiNOCO radio support (station firmware v.8.74)
Issues Fixed
- Fixed Receiver Stuck Detection
- Added IP Fragmentation support for UDP tunnels.
- Resolved TurboCell latency issues with a dual-radio configuration. This fix should drastically decrease the latency
of packets passing through the second TurboCell radio interface.
- Updated TurboCell Access Control List (ACL) to support 100 users (was 16 users).
Known Issues
- The MAC Authorization Access Control List (ACL) supports import of up to 64 entries, but will only authenticate
up to entry 31.
- Some Avaya radio cards with part numbers that end in "B" (for example, P/N 01064/B) may not work correctly
with TurboCell.
KarlNet developers are working to resolve these issues.
Note
- Software version 4.43k improves latency on dual-radio configurations. Users with applications sensitive to network
latency received experimental software (for example, version 4.31r) that changed the minimum polling rate from
1 Hz to 5 Hz. While this change offered some improvement, it did not affect the source of the latency. Version
4.43k addresses the source (as noted in the Trackers Fixed area above) and permanently reduces the latency without
the overhead associated with increased polling. The minimum polling rate in 4.43k is 1 Hz. KarlNet recommends that
users who are currently using the experimental software upgrade to 4.43k to take advantage of these improvements.
Return to the Downloads page.

home | customers | solutions | corporate | news | support | partners | contact us
|